Digitrax SoundFX SDXH186MT Handbuch - Seite 8

Blättern Sie online oder laden Sie pdf Handbuch für Controller Digitrax SoundFX SDXH186MT herunter. Digitrax SoundFX SDXH186MT 16 Seiten. Complete train control

Digitrax SoundFX SDXH186MT Handbuch
Bell and Air Effect Rates CV146-149
CV146 controls the bell rate or time between ring of the bell, it has a
range from 1-100 with each increment adding 24ms of delay. CV147 con-
trols the drier rate, it has a rage from 1-64 with each increment adding
about 2 seconds. CV148 controls the Compressor/ Air pump start rate
and CV149 controls how long the Compressor/ Air Pump runs.
Auto Coupler Sequence Threshold Value CV151
CV151 controls the threshold at which coupler and brake sounds are
automatically played when locomotive direction is changed and function
3 is enabled. CV151 has a range of 0-60.
Changing the Sound Scheme on your SDHX166D CV60,
150, 157
The SDHX166D comes preloaded with 8 different sound schemes, 6 die-
sel and 2 Steam. These schemes can be selected using CV60. Each diesel
scheme can be configured with one of 8 different horns using CV150 and
one of 4 different bells using CV157. Each Steam scheme can be config-
ured with one of 3 whistles using CV150 and one of 4 bells using CV157.
To enable playable volume for your selected horn or whistle add 128 to
the selected value (ex. Playable volume on horn 2 is enabled with a value
of 130, 02+128=130)
© 2017 Digitrax, Inc.
— 8 —
www.digitrax.com