Bell and Air Effect Rates CV146-149
CV146 controls the bell rate or time between ring of the bell, it has a
range from 1-100 with each increment adding 24ms of delay. CV147 con-
trols the drier rate, it has a rage from 1-64 with each increment adding
about 2 seconds. CV148 controls the Compressor/ Air pump start rate
and CV149 controls how long the Compressor/ Air Pump runs.
Auto Coupler Sequence Threshold Value CV151
CV151 controls the threshold at which coupler and brake sounds are
automatically played when locomotive direction is changed and function
3 is enabled. CV151 has a range of 0-60.
Changing the Sound Scheme on your SDHX166D CV60,
150, 157
The SDHX166D comes preloaded with 8 different sound schemes, 6 die-
sel and 2 Steam. These schemes can be selected using CV60. Each diesel
scheme can be configured with one of 8 different horns using CV150 and
one of 4 different bells using CV157. Each Steam scheme can be config-
ured with one of 3 whistles using CV150 and one of 4 bells using CV157.
To enable playable volume for your selected horn or whistle add 128 to
the selected value (ex. Playable volume on horn 2 is enabled with a value
of 130, 02+128=130)