Digitroll DMS 06 Gebrauchsanweisung - Seite 5

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Kontrollsysteme Digitroll DMS 06 herunter. Digitroll DMS 06 12 Seiten. Planter monitor

INSTALLATION

MONITOR LOCATION
The monitor has to be mounted in the compartment at a well visible place with
the attaching clip being in lower or upper position using 2 plate screws. Avoid
direct sunlight to reach the display. The most favourable location for the
monitor is right under the compartment roof.
The monitor is to be connected to the 12V system of the power machine
behind a minimum 1A fuse with regard to polarity (red = positive, blue =
negative). The wire between the connection point and the 12V
accumulator of the power machine should be as short as possible.
Connect the sensors' extension cable to the monitor.
Do not share power supply with devices that may cause interference (fans,
magnetic valves, etc.).
Welding works are only allowed when both power cables of the monitor
are disconnected from the tractor's electronic system.

CONTROL DEVICE

Stand-by signal
(red light)
ON and TEST button
(searching seed
sensors, checking
dust level)
Horn
IN TELLIGENT SENSOR TECHNOLOGY
S tring C ircuitry
0,25
0,5
0,75
1
2
3
TEST
DIGITROLL
DMS 06 PLANTER MONITOR
Switched on, 12V OUT= continuous light
Sensor search
= darkens for a short time
Cable short
= dark during operation
Switched off
= dark
1
1,5
2
sec
4
5
6 ROWS
OUT
AUTO OFF
INSTALLATION
Selectable time
intervals (0.25 – 2 sec)
error = red light
Number of seeder
elements (1-6)
Adjusting sensitivity of
error indication
(max. time period of
seed shortfall)
5