Fimer R25 Series Handbuch - Seite 5
Blättern Sie online oder laden Sie pdf Handbuch für Modem Fimer R25 Series herunter. Fimer R25 Series 12 Seiten. Grid connected pv inverter internal and external gsm modem user guide for single-phase inverter
Auch für Fimer R25 Series: Benutzerhandbuch (16 seiten)

________________________________________________________________________________
Please read and observe the installation instructions supplied by the sensor's manufacturer
4 Cabling of sensor
4.1 Connecting using the soldered connector
4.2 Connecting temperature sensors
X4 pin 17
PT1000 input, module temperature
X4 pin 4
PT1000 ground, module temperature
X4 pin 18
PT1000 input, ambient temperature sensor
X4 pin 5
PT1000 ground, ambient temperature
X4 pin 10
LM35 input, module temperature
X4 pin 19
LM35 ground, module temperature
5 Setting the Sensor Functions of the Inverter.
Note: All functions can be accessed and set with the aid of the final customer password (password
level 1). Button combination: ▲..►..▼..▲..►..▼ and complete by pressing [OK]. Further
information with regard to controlling the inverter display can be found in the User Manual for
Fimer's 1-phase inverters.
All parameters required for operating the sensor can be found under the main menu item
"Environment"
5.1 Setting the irradiation sensor of Sensor Box
Parameter number 213: Irradiation sensor type
Menu
Short description
Default Value
Value = 0 no irradiation sensor connected
________________________________________________________________________________
Environment
TYPIRR
0
.
3