The dimensions
shown are for the recommended
spacing.
For cabinet installation, with a door, the minimum ventilation
__
, (22.9 c rn)
1
(10.2crn) (80.0crn) (2.5cm) (2.5cm) (68.6crn) (2.5cm)
The washer can be installed using the standpipe drain system
(floor or wall), the laundry tub drain system, or the floor drain
system. Select the drain hose installation method you need. (See
"Alternate Parts.")
30" rain,
(76=2 cml
Standpipe
drain system - wall or floor
(view I & 2)
The standpipe drain requires a minimum diameter standpipe of
2 in. (5 cm). The minimum carry-away capacity can be no less
than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30 in. (76.2 cm) high
and no higher than 96 in. (2.4 m) from the bottom of the washer.
Laundry tub drain system (view 1)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
of the laundry tub must be at least 30 in. (76.2 cm) above the
floor.
Floor drain system (view 2)
The floor drain system requires a siphon break that may be
purchased separately. (See "Alternate Parts.")
The siphon break must be a minimum of 28 in. (71 cm) from the
bottom of the washer. Additional hoses might be needed.
EtectricaJ
Shock
Hazard
Plug into a grounded
3 prong
outlet.
Do not remove
ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure
to follow
these
instructions
can result
in
death,
fire,
or electrical
shock.
A 120-volt, 60-Hz., AC-only, 15- or 20-ampere, fused
electrical supply is required. Time-delay fuse or circuit
breaker is recommended.
It is recommended
that a separate
circuit serving only this appliance be provided.
This washer is equipped with a power supply cord having a
3 prong grounding plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type
outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the
washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
2
..............
1
©
1.3 prong grounding plug
2. 3 prong grounding-type
wall receptacle
3. Grounding prong
4. Power supply cord