Whirlpool 36inch Installationsanleitung und Gebrauchs- und Pflegeanleitung - Seite 7

Blättern Sie online oder laden Sie pdf Installationsanleitung und Gebrauchs- und Pflegeanleitung für Lüftungshaube Whirlpool 36inch herunter. Whirlpool 36inch 24 Seiten. Range hood 30" and 36" (76.2 cm and 91.4 cm) vented

It is recommended that the vent system be installed before
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
To avoid damage or dirt, place a thick, heavy covering over
countertop, cooktop, or range.
1. Disconnect power.
2. Determine which venting method to use: roof or wall.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4. If cabinet has recessed bottom, add wood filler strips on each
side. Locate screws to attach filler strips in locations shown.
3" (7.6 cm)
3" (7.6 cm)
Determine Wiring Hole Location
Cut only one 1¹⁄₄" (3.2 cm) diameter wiring access hole.
See Step 2 for wiring hole location instructions. Either wiring hole
can be used.
1. Determine and clearly mark a vertical centerline on the wall
and cabinet in the area the vent opening will be made.
A. Centerline

INSTALLATION INSTRUCTIONS

Prepare Location

Wood filler strips
(recessed cabinet
bottoms only)
Cabinet
bottom
Wall
A
2. To wire through top:
Mark a line 7¹⁄₂" (19.0 cm) from the right of the centerline on
the underside of the cabinet. Mark the point on this line that is
2" (5.0 cm) from back wall. Drill a 1¹⁄₄" (3.2 cm) diameter hole
through the cabinet at this point.
7 ¹⁄₂"
(19 cm)
To wire through rear wall:
Mark a line 7¹⁄₂" (19.0 cm) from the right of the centerline on
the underside of the cabinet. Mark the point on this line that
is ³⁄₄" (1.9 cm) from the underside of the cabinet. Drill a
1¹⁄₄" (3.2 cm) diameter hole through the rear wall at this point.
3. Use saber or keyhole saw to cut a 7" (17.8 cm) diameter
opening.
*5"
(12.7 cm)
*From wall, not
cabinet frame
4. Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See "Venting Requirements" section.
5. Use caulking to seal exterior wall or roof opening around the
cap.
2" (5.1 cm)
from wall,
not cabinet
frame
Centerline
³⁄₄" (1.9 cm)
7 ¹⁄₂"
(19 cm)
Centerline
7 ¹/₄" (18.4 cm) diam.
cabinet cutouts
7