Calex ExTemp Series Benutzerhandbuch - Seite 6

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Temperaturregler Calex ExTemp Series herunter. Calex ExTemp Series 17 Seiten. Intrinsically safe infrared temperature sensor and lct loop configuration tool

ACCESSORIES
A range of accessories to suit different applications and industrial environments is available as
follows. These may be ordered at any time and added on-site:
LCT Loop Configuration Tool (USB adapter)
Fixed and adjustable mounting brackets
Air purge collar
OPTIONS
The following options are available. Options are factory installed and must be ordered with
the sensor.
Certificate of calibration
Extended cable (25 m max. factory-fitted; contct Calex for information about
extending the cable)
OPTICS
The below chart shows the measured spot diameter at the given distances from the sensing
head and assumes 90% energy. The sensor may be used at longer distances than shown
below, with a larger measured spot size.
Distance: Sensor to object (inches)
0
0.5
11.0
0
Distance: Sensor to object (mm)
Distance: Sensor to object (inches)
0
0.5
11.0
0
Distance: Sensor to object (mm)

INSTALLATION AND MAINTENANCE

The installation process consists of the following stages:
1
Preparation
2
Mechanical installation
3
Electrical installation
Please read the following sections thoroughly before proceeding with the installation.
6
4
8
4.4
2.4
D:S 2:1
61.9
111.9
100
200
-21
19.7
39.4
1.8
1.1
D:S 30:1
28.6
45.2
500
1000
-301
Distance: Sensor to object (inches)
0
19.7
1.8
0.5
D:S 15:1
11.0
45.2
0
500
Distance: Sensor to object (mm)
-151
Distance: Sensor to object (inches)
0
3.9
0.5
0.20
11.0
5.0
0
100
Distance: Sensor to object (mm)
-CF
39.4
3.1
78.6
1000
7.9
0.49
12.5
200