eControls Comfort365 C365C32 Handbuch für Installateure - Seite 2
Blättern Sie online oder laden Sie pdf Handbuch für Installateure für Thermostat eControls Comfort365 C365C32 herunter. eControls Comfort365 C365C32 8 Seiten. Wiring hub, model wh11 and wh32
Auch für eControls Comfort365 C365C32: Handbuch für Installateure (4 seiten)
SEPARATE THE C365 SUBBASE
Place a slotted screwdiriver in the slots as shown and rotate to
remove subbase from the C365 housing.
ATTACH THE SUBBASE TO THE WALL
Attach the subbase to an interior wall and about 5-feet above
the floor as shown using the screws and wall anchors supplied.
The wiring to the HVAC equipment passes through the opening
next to the terminals.
5 V
G N D
S A
S B
C 3 6 5
C 3 2
INSTALL TWO AA BATTERIES
The batteries power the clock when 24VAC power is lost. Slide
the battery cover downward and install the two AA batteries as
shown.
INSTALL UPSTAIRS & DOWNSTAIRS DAMPERS
Refer to the WH11 or WH32 Wiring Hub Installation manual for
instructions on wiring dampers to the wiring hub.
Install an R80CJ damper in the duct supplying air to the upstairs.
Install a second R80CJ damper in the duct supplying air to the
downstairs. Each damper uses 2.4VA of power.
When two or more dampers are required to define the upstairs or
downstairs zones, the second damper may be plugged into the
connector marked OUT on the first damper. LEDS on the
damper actuator indicate when the damper is fully open (green)
or fully closed (red).
Ensure that damper installation does not cause
!
obstruction to the damper blade.
INSTALL UPSTAIRS TEMPERATURE SENSOR
Refer to the WH11 or WH32 Wiring Hub Installation manual for
instructions on wiring upstairs temperature sensors to the wiring
hub or connecting wireless sensors to the wiring hub.
Wired Sensors: One or two wired temperature sensors can be
installed and the temperatures are averaged. Model TS510W is
used for single sensor installations. Model TS520W is used for
dual sensor installations.
Wireless Sensors: One or two wireless temperature sensors can
be installed and the temperatures are averaged. Wireless
sensors require Model ELR1 plug in radio module. The radio
module plugs into the WH11 or WH32 wiring hub.
2
Green LED
Red LED