MAINTENANCE

WARNING: DISCONNECT THE SANDBLASTER FROM THE AIR SUPPLY
BEFORE CHANGING ACCESSORIES, ATTEMPTING TO MOVE THE
SANDBLASTER OR PERFORMING ANY MAINTENANCE.
1. Keep your sandblaster clean and protect it from damage.
2. When initially pressurising, check for leaks at the top of the tank and at all
hoses and fittings.
3. Leaking joints maybe repaired by replacing worn or damaged parts or
using teflon tape.
4. Check for worn abrasive hose and fittings.
5. Watch for leaks, blistering, bulging or thinning of the hose.
6. Replace any parts which appear worn.
AIR FILTER
DRAINING
Condensation will collect in the air filter which must be drained manually.
1. Drain the air filter by pulling down
on the drain plug until all the water
comes out, see Fig 18.
CLEANING/REPLACING
1. Press the release catch and
unscrew the condensation
chamber, see Fig 19.