Clarke BIP1500 Handbuch für Betrieb und Wartung - Seite 5

Blättern Sie online oder laden Sie pdf Handbuch für Betrieb und Wartung für Water Pump Clarke BIP1500 herunter. Clarke BIP1500 17 Seiten. 1” electric water pump

Clarke BIP1500 Handbuch für Betrieb und Wartung

FITTING THE CABLE

Do not attempt electrical installation
work if you are in any doubt as to
how it should be done correctly.
Consult a qualified electrician.
The pump must be wired according
to the diagram, after removing the
cover plate, ensuring the following
principles are observed:
• The cable used must be the
correct size to ensure it is a tight
fit in the cable gland.
• Ensure the cable gland is
correctly used. The clamp must
firmly hold the outer cable
sheath and not the wires.
• Fit a crimp style ring terminal to
the earth wire and make sure
that it is correctly connected to
the earth terminal. The ring
terminal should be placed
between the two washers, and
the screw suitably tightened.

FITTING THE PLUG

WARNING! THE WIRES IN THE POWER CABLE SHOULD BE
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
(Blue = Neutral
To ensure that the colours of the wires in the power cable correspond with the
markings on the terminals of your plug, proceed as follows.
he wire which is coloured Blue must be connected to the terminal
• T
which is marked N or coloured Black.
• The wire which is coloured Brown must be connected to the terminal
which is marked L or coloured Red.
• The wire which is coloured Yellow and Green must be connected to
the terminal which is marked E or
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Brown = Live
Yellow and Green = Earth
or coloured Green
5