ELECTRICAL CONNECTIONS

WARNING: THE INSTALLATION OF THIS APPLIANCE SHOULD BE CARRIED
OUT BY A COMPETENT ELECTRICIAN AND BE IN ACCORDANCE WITH THE
CURRENT IEE WIRING REGULATIONS (BS7671-2:2008).
This machine MUST be connected to a 400 Volt, 3 phase 50Hz supply through a
suitably fused isolator switch. It cannot be operated from a single phase
supply.
A trailing lead is provided and should be wired to a 3 phase plug (not
supplied) as follows.
• Connect the GREEN or GREEN & YELLOW
coloured wire to the terminal marked with
the letter "E" or the Earth symbol "
• Connect the remaining Brown, Black and
Grey wires to the terminals marked "L1", "L2"
and "L3".
• No connection to the Neutral terminal is
required.
Due to these high currents, the product must only be connected to a 3 phase
supply capable of supporting these loads (plus an acceptable degree of
headroom). This supply must be protected by a suitably rated circuit breaker
(or breakers) and isolator.
If in any doubt, consult a qualified electrician. DO NOT attempt any electrical
repairs yourself.