Clarus Technologies PCS-25 Benutzerhandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Reinigungsgeräte Clarus Technologies PCS-25 herunter. Clarus Technologies PCS-25 14 Seiten. Cleaning stations
Auch für Clarus Technologies PCS-25: Benutzerhandbuch (16 seiten)
If the optional Air Tool with Air Pump was purchased for your Parts Washer, you
will have an air nozzle/handle hanging on the inside of the Parts Washer lid and
an on/off switch labeled "Air Tool". To activate the air tool first turn the switch
to "ON", this will start the compressor. Next, take hold of the Air Tool, point it
down and away from your body and depress the trigger on the handle. This will
release the pressurized air for use with the Parts Washer.
Regulated Shop Air Operated Air Tool:
If the optional regulated "Shop Air" model was purchased, hook up the Shop Air
Hose to the air regulator located on the backside of the lower shelf. Manually
adjust the amount of air needed by pulling up the knob on the regulator and
turning it to the appropriate setting. When the proper amount of air is achieved,
push knob down to lock your setting. With this set-up, air will always be
available at the nozzle.
Agitation Tank/Pump Assembly:
The PCS-25 and PCS-15 come with an optional stainless steel soak tank ("Soak
Tank") and a UL approved submersible agitation pump. The "on/off" switch for
the Soak Tank is located on the lower left hand corner of the lid.
Prior to turning the agitation tank on:
1) Place the stainless steel tank along the left hand side wall of the working surface,
2) Turn the PCS-25/PCS-15 on by depressing the green "on" switch.
3) As the solvent begins to flow, use the cleaning brush and/or nozzle to fill the
stainless steel soak tank until it covers the pump.
4) Once the soak tank is full you can turn on the pump. The agitation pump will
stay on until it is manually turned off.
Fluid Nozzle – shutoff.
E.
The fluid nozzle flow can be adjusted or turned off by turning the yellow valve handle at
the nozzle's base.
F.
Filter Differential Pressure Gauge.
The PCS-25/WCS-25 model and the PCS-15 use a pressure gauge to indicate when the
filters need replacing. Replace filters when the gauge reads 40 PSI. Operating system
beyond 40 PSI will not damage the unit, however, the quality of the solvent will degrade
beyond 40 PSI.
G.
Fusible Link.
9