ACORN AQUA A112408B/S-VR-UBL Anweisungen für Installation, Betrieb und Wartung - Seite 3
Blättern Sie online oder laden Sie pdf Anweisungen für Installation, Betrieb und Wartung für Wasserspender ACORN AQUA A112408B/S-VR-UBL herunter. ACORN AQUA A112408B/S-VR-UBL 8 Seiten. Vandal resistant refrigerated universal bi-level aquaaccess barrier free, wall mounted water cooler
A112408S/B-VR VANDAL RESISTANT REFRIGERATED UNIVERSAL BI-LEVEL AQUAACCESS
(Alernate Configuration Left Unit Low with Right Unit High)
18 1 2 "
[470]
C
*20 7 8 "
[530]
TAILPIECE
GENERAL NOTES:
1.
ALL DIMENSIONS ARE IN INCHES [MM]
2.
ALLOW 4 INCHES [102 MM] MINIMUM CLEARANCE PER SIDE FOR VENTILATION
*3.
DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL
DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES.
4.
STOP VALVE, TRAP, & ELECTRICAL OUTLET NOT SUPPLIED.
5.
IMPORTANT: COOLERS MUST BE ATTACHED TO WALL WITH ANCHOR SCREWS.
IMPORTANT:
1. Waste P-Trap, Water Supply Service Angle Stop Valve and 2" x 4" Electrical Plug-In Receptacle
to be supplied by others in accordance with local codes. A metallic p-trap (by others) must be
used for the drain connection.
2. Provide 4" minimum clear space on fixture sides to allow for proper ventilation through cabinet
louvers.
3. Water supply is 3/8" Outside Diameter copper tube. Waste is 1-1/4" Outside Diameter.
4. Completely flush supply lines of all foreign debris before connecting to fixture. Water cooler
designed to not affect taste, odor, color, or sediment. Optional water filter (Wf1) is available should
any of these problems arise from the water supply.
5. Do NOT solder copper tube when inserted into the coupler as damage to the o-ring will result.
6. All burrs must be removed from outside of cut tubes before inserting into coupler or other
components.
7. Power supply must be identical in voltage, cycle and phase to that specified on the cooler data
plate. Electrical outlet and furnished power cord with plug must be used to supply power to
fixture. Do NOT wire compressor directly to the power supply.
8. This unit must be grounded per the requirements of applicable electrical codes.
9. WARNING: Warranty is voided if installation is not made following current Acorn Aqua
installation instructions and if components are assembled to the fixture that is not approved by
Acorn Aqua.
10. Fixture operates within water pressure range of 20 to 105 psig. Acorn Aqua will not warranty
fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or
higher than 105 psig. A pressure regulator must be furnished by others on supply line if inlet
pressure is greater than 105 psig.
11. Due to cold waste water, Acorn Aqua recommends that p-trap supplied by installer be insulated
to prevent excessive condensation.
12. Per UPC 609.10- All building water supply systems in which quick acting valves are installed
shall be provided with devices to absorb the hammer caused by high pressure resulting from the
quick closing of the valve. These pressure-absorbing devices shall be approved mechanical
devices. Water pressure-absorbing devices will be installed as close as possible to the quick
closing valve.
*38 3 4 "
*37 5 8 "
[984]
[956]
ORIFICE
RIM
HEIGHT
HEIGHT
*32 3 4 "
[832]
*31 5 8 "
ORIFICE
HEIGHT
[803]
RIM
HEIGHT
Page 3 of 8
6 5 8 "
6 5 8 "
Ø 3 8 " [10]
[168]
[168]
3 HOLES
EACH
BRACKET
Ø 1 4 " [6]
4 ANCHOR
HOLES
*29 1 8 "
[740]
4 1 4 "
*15 5 8 "
[108]
[397]
7 7 8 "
7 7 8 "
[200]
[200]
A
Ø3/8" [10] O.D. COPPER TUBE SUPPLY
B
ELECTRICAL OUTLET
C
Ø1-1/4" [32] O.D. P-TRAP (NOT FURNISHED)
18 5 8 "
[473]
18 1 2 "
[470]
A
AIR FLOW
B
5 1 4 "
*27 7 8 "
[133]
*22 3 8 "
*21 5 8 "
[708]
6 1 2 "
[568]
[549]
[165]
*35 1 8 "
[892]