NOTE: Make all connections in accordance with local codes.
Switch power off at service panel and lock the service disconnect-
ing means before wiring the unit. Power cables, connectors, con-
duit etc. not supplied.
Wiring from Service Panel
1.
A 15A circuit is required for installation. It is recommended to
dedicate the circuit.
2.
Run three wires: # 14 AWG (black, white and green) in conduit
from service panel to hood.
Make the electrical "whip" long enough to reach to the countertop
below the installed hood.
Wiring At the Hood for Single Blower 600 CFM or Dual Blower
1200 CFM Interior Ventilator:
Flexible
Metal
Conduit
Duct
Hood Stack
"Power Supply" and secure with appropriate connector.
7.
Lift liner up into hood, reaching up through exhaust outlet to
transition top, guide liner into place. Re-secure liner to hood body
using #8 x ½" Phillips head sheet metal screws.
8.
Lift Light Only Panel up to liner and connect black wire to
black and white to white. Secure Light Panel to liner wall with
screws supplied. (In wall mount hood secure Screw Covering
Panel.)
9.
Lift Light/Switch Control Panel up to liner.
10.
Complete Power Supply Connections: connect black wire from
service panel to black in Light/Control Switch Panel, white to white
and green to green.
11.
Secure Light/Switch Control Panel to liner wall with screws
supplied.
12.
Reattach mounted-blower plate(s) to ceiling of liner.
13.
Replug blower(s) harness(es) to connections at top right of
motor.
Hoods with Abbaka Internal Ventilator
1.
Position hood liner on
counter below hood.
2.
Remove Light/Control
nd
Switch Panel and 2
Light
Panel or (Screw Covering
Panel in wall mount hood) from
liner.
3.
Remove filters from liner.
4.
Unplug blower(s) harness
(es) located at the upper right
of each motor(s).
5.
Unscrew blower plate(s)
from "ceiling" of liner and set
mounted-blower plate(s) aside.
6.
Feed conduit from service
panel into knock out labeled
7
Electrical
120vAC
Hood Shell
Liner
Liner Knock-out
Top View
Power Supply Knock-Out
Internal Ventilator