Wall Mounting Instructions

Failure to follow these instructions will void your warranty and
For Masonry Walls
Screw
Plastic
Anchor
1.) Predrill the correct diameter predrill
in the wall with a masonry drill bit.
2.) Tap in the plastic anchor
3.) Attach the unit to the wall with the .
correct length screw
Snaptoggle
Anchor
1.)
Drill a 1/2" diameter hole in the sheetrock.
2.)
Insert the Snaptoggle anchor into the 1/2" hole. Hold ends of straps together and pull toward you
until channel rests behind wall. Ratchet cap along straps until cap is flush with wall.
3.)
Push thumb side to side to snap off straps level with flange of cap.
4.)
Place unit over flange and insert bolt that came with the Snaptoggle and tighten bolt.
could result in injury.
Use the correct wall
predrill for your
Plastic Anchor
.
For Sheetrock Walls
1/2"
Hole
For Wood Stud Walls
Wood Stud
2"-3" Lag
Screw
1.) Predrill a 1/8" hole in the through the
wall surface and into the wood stud.
2.) Attach the unit to the wall with a 2"-3"
Lag Screw.
7
1/8"
Predrill
Snaptoggle
Anchor in set
position
Bolt