2.3 Ethernet Communication

2.3.1

Ethernet Communication Software

A packet sending and receiving software such as
Sender'
is required to test the UDP over IP (UDP/IP) communication between the ACS-200
and the computer. To test the TCP over IP (TCP/IP) communication, just a standard web
browser such as Chrome, Edge, Safari, Opera etc will suffice.
2.3.2

Preparing the Network

To prepare your network for the installation of the ACS-200, a static and dedicated IP
address will need to be assigned to each individual ACS-200 connecting to the network, as
well as to the computer that will be used to control them.
A unique Port number for the UDP/IP communication between the ACS-200 and the
computer will also need to be assigned to the system. It is imperative that these IP
addresses and Port number are unique on the network without any clashes, otherwise the
communication will be hampered, and devices rendered unusable. These should also be
clearly recorded for future reference.
2.3.3

Configuring and Connecting the Units

Once the IP addresses and Port number have been assigned to all the ACS-200 units, they
will need to be configured with their individual IP address, the IP address of the controlling
computer and the UDP Port number for the system.
For initial configuration, each ACS-200 unit will have to be connected in turn to a computer
using a serial connection by following the instructions in the previous section.
The following commands will be required for implementing this on each ACS-200 unit
connecting to the network:
Action
Set ACS-200 (local) IP Address
Set Controller (remote) IP Address
Set UDP Port Number
The following commands can be used to check that the configuration has been successful:
Action
Get ACS-200 (local) IP Address
Get Controller (remote) IP Address
Get UDP Port Number
Get all the information for the unit
When the units have been successfully configured, they will need to reboot. This can be
done either by cycling the power to the unit or by using the command '
'UDP – Sender/Receiver'
Command
Parameter
local_ip,xxx.xxx.xxx.xxx
remote_ip,xxx.xxx.xxx.xxx
port,xxxx
Command
local_ip
remote_ip
port
settings
'Packet
or
Parameter
example
192.168.1.250
192.168.1.150
2222
reset'
. Once all the
6