3 Functions, Commands and Errors

3.1 Functions List

Function
Description
unlock
Opens a lock or closes it when hold feature is on and the lock is already open
interlock
Interlocking allows only one lock to be opened at any given time
hold
Hold feature holds open the lock after opening, until a second pulse is received
state
Retrieves the status, either of the whole system or an individual lock
detect
Detects all the locks (only the closed ones) that are connected to the system
open_alarm
Door Open Alarm - raised when a door has been left open for a period of time
intrusion_alarm
Intrusion Alarm - raised when a lock has been opened without authorisation
open_duration
Door Open Duration – Duration after which Door Open Alarm will be triggered
relock_duration
Lock Relock Duration – Duration after which an open lock will relock itself

3.2 Commands List

Command
Parameter (x) Action
1 to 10
unlock,x
all
0 or 1
interlock,x
0 or 1
hold,x
0 or 1
open_alarm,x
0 or 1
intrusion_alarm,x
none
open_duration
5 to 300
open_duration,x
relock_duration
none
relock_duration,x
0 to 60
mac
none
mac,x:x:x:x:x:x
00 to FF
local_ip
none
local_ip,x.x.x.x
0 to 255
remote_ip
none
remote_ip,x.x.x.x
0 to 255
port
none
port,x
0 to 65535
settings
none
state
none
1 to 10
state,x
none
detect
none
version
none
id
none
model
none
info
none
reset
Opens lock connected to the corresponding port number
Opens all locks connected to the system sequentially
Turns Interlocking either on (1) or off (0)
Turns Hold Feature either on (1) or off (0)
Turns Door Open Alarm either on (1) or off (0)
Turns Intrusion Alarm either on (1) or off (0)
Displays the current Door Open Duration in seconds
Sets the Door Open Duration for the system in seconds
Displays the current Lock Relock Duration in seconds
Sets the Lock Relock Duration for the system in seconds
Displays the current MAC Address of the device
Sets the MAC Address of the device
Displays the current IP Address of the device
Sets the local IP Address of the device
Displays the current IP Address of the controlling device
Sets the IP Address of the remote controlling device
Displays the current UDP Port Number for the system
Sets the Port Number for UDP Communication
Displays all the current device settings
Displays the status of the whole system
Displays the status of the corresponding lock
Detects all the closed locks connected to the system
Displays the installed firmware version
Displays the serial number of the device
Displays the model number of the device
Displays all the information for the device
Resets the device