3. Technical settings
Setting TPI, Delayed or Optimum Start
3.1
1. Switch the slider to OFF. Press and keep holding the A
and H buttons together (under the fascia), then press
the Next
Release all buttons.
2. Press the +/– buttons to choose between:-
OFF: The programme will run according to settings
DS (dL StAr DS): When ON, the programmer will run in
Delayed Start mode. The start of the next programme
may be delayed up to 45 minutes depending on the
room temperature
S (OP StAr OS): When ON, the programmer will run in
Optimum Start mode
3. Press the Next
turn OP STOP (Optimum Stop) ON/OFF.
4. Press the Next
+/– to choose between:-
OFF: Working under normal swing value
3 Cycles: ON/OFF one cycle is 20 minutes. This is
recommended for oil boilers
6 Cycles: ON/OFF one cycle is 10 minutes. This is
recommended for gas boilers (default setting)
5. Press the Next
Swing and Calibration settings below.
12
button to enter the technical settings.
button and press the +/– buttons to
button to enter the TPI settings. Press
button to continue to the Sensitivity/