ARTHUR HOLM AHDTL Benutzerhandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Hebesysteme ARTHUR HOLM AHDTL herunter. ARTHUR HOLM AHDTL 20 Seiten. Universal motorized system for gooseneck microphones
Auch für ARTHUR HOLM AHDTL: Benutzerhandbuch (13 seiten)

AHnet protocol

COMMUNICATIONS PROTOCOL
Communication
Connection
Wiring
SPEED & CONFIGURATION
Baud Rate
Data Bits
Parity
Stop Bits
WIRING DIAGRAM
1
2
3
4
5
6
7
8
CONNECTION
Pins 1 & 2
Pins 3 & 6
Protocol to control the DynamicTalk by addressable RS422 bus.
You can connect up to 30 devices on the same RS422 bus.
You can use a AH Interface Ethernet, to control the RS422 bus.
The units should have a set address and the address must start by 1.
Maximum cable length between ends, 500m/1640 ft.
14
RS422
RJ45
CAT-5
38400
8
None
1
Data TX +
Data TX –
Data RX +
NC
NC
Data RX
NC
NC
The units respond
The units receive instructions
RJ-45