Technical lnformation
Base plate
Working space to the right of the needle
Needle throw and sewing speed
4.5mm
6.0mm
8.0mm
12.0mm
Machines with cam- device for utility and decorative stitches, stitches per minute for
decorative -utility stitch
6.0mm 2,300 2,800
8.0mm 2,100 2,800
12.0mm 1,800 2,600
Machines with other extra attachments such as:
Puller
Stitch
displacement
Stitch length forward and reverse:
Max. presser foot lift:
Needle system:
Shuttle system:
Thread tension:
Raising presser foot:
265
476
:476×178mm
:265×128mm
2800 stitches per minute
2800 stitches per minute
2600 stitches per minute
2200 stitches per minute
as basic model
left-centre-right
5.5mm
8.5mm
12.0mm needle throw =134R,
No.70-120
continuous double rotation,
transverse position
double thread tension
knee lever with extra upper holding
position.
2
Important points to note:
·
Oil machine thoroughly before
using for first time.
When doing so, strictly observe
●
instructions.
Check
that
the
mains
●
corresponds to the voltage given on
the motor ,if the voltages are not the
same, do not on any
operate the machine.
Check the guards for finger, take-
●
up lever and belt are all present.
When the machine is running the hand
●
wheel should turn anti-clockwise , if it
dose not reverse the terminals on the
motor.
Use
only
recommended
●
system.
Clean machine regularly.
●
Do not start machine until the fabric
●
is in position under the presser foot.
When removing fabric always bring
●
thread
take-up
lever
at
position.
For the first 2 weeks, run machine
●
at only 3/4 of its maximum speed.
The presser foot can be raised either
●
with the hand lever or with the knee
lever.
When making adjustments to the
●
machine and when sewing is finished
the machine and when sewing is
finished the motor should be switched
off or disconnected at the mains.
When using a clutch motor , wait
until it has stopped.
voltage
account
needle
highest