DOEPFER Dark link Benutzerhandbuch - Seite 15

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Aufnahmegeräte DOEPFER Dark link herunter. DOEPFER Dark link 20 Seiten. Usb/midi-to-cv/gate interface
Auch für DOEPFER Dark link: Benutzerhandbuch (20 seiten)

DOEPFER
To reset the device, depress and hold the learn button while the power supply is plugged in. The LED will
light up and you have to keep the button depressed for a few seconds until the LED starts flashing. Pres-
sing the button again gets you back into normal operation mode and the LED will turn on.
After resetting, Dark Link's parameters are set to the following default values:
- MIDI channel 1
- Reference note 36 (i.e. the lowest „C" on a standard 5-octave keyboard)
- Retrigger: on
- CV3: volume (controller #7)
- CV4: modulation (controller #1)
- Key assign mode: highest note
- Internal Arp-Tempo: approx. 120 BPM
- Gate length: 6
- Octave: 1
- Arppeggiator Sync: internal
These values are identical with the factory default settings.

3.7. Firmware Update

Dark Link's firmware can easily be updated via USB. In case a new firmware version is available, you can
download it from our website (www.doepfer.de). A detailed description of the update process can be found
in the additional technical description of Dark Link. You can download this documentation here:
www.doepfer.de -> Products -> Dark Link -> Additional technical documentation
Dark link
15
Functions