To reset the device, depress and hold the learn button while the power supply is plugged in. The LED will
light up and you have to keep the button depressed for a few seconds until the LED starts flashing. Pres-
sing the button again gets you back into normal operation mode and the LED will turn on.
After resetting, Dark Link's parameters are set to the following default values:
- MIDI channel 1
- Reference note 36 (i.e. the lowest „C" on a standard 5-octave keyboard)
- Retrigger: on
- CV3: volume (controller #7)
- CV4: modulation (controller #1)
- Key assign mode: highest note
- Internal Arp-Tempo: approx. 120 BPM
- Gate length: 6
- Octave: 1
- Arppeggiator Sync: internal
These values are identical with the factory default settings.
3.7. Firmware Update
Dark Link's firmware can easily be updated via USB. In case a new firmware version is available, you can
download it from our website (www.doepfer.de). A detailed description of the update process can be found
in the additional technical description of Dark Link. You can download this documentation here:
www.doepfer.de -> Products -> Dark Link -> Additional technical documentation