Ashcroft GC35 Handbuch für Installation und Wartung - Seite 11
Blättern Sie online oder laden Sie pdf Handbuch für Installation und Wartung für Zubehör Ashcroft GC35 herunter. Ashcroft GC35 20 Seiten. Heavy duty digital pressure sensor
Auch für Ashcroft GC35: Schnellstart-Anleitung (4 seiten), Schnellstart-Anleitung (4 seiten)
Measurement Mode
MODE
Press 3 sec.
or longer
Function Setting Mode
Select Comparator Mode
MODE
Comparator Operation
Selection
MODE
Filter Setting
MODE
Power-save setting
MODE
LED Ring Feature Setting
MODE
Display Unit Setting
MODE
MODE
Energy-Saving Mode Setting
The unit is equipped with automatic display turn-off feature. If user wishes to turn-on the display
only when reading the display, or to use the unit mainly for an electrical output reading, this fea-
ture can be used.
LED Ring Operation Setting
lr0 LED ring is off.(no linkage)
Lr1 LED ring turns Red when comparator 1 is ON, and turn Blue or Green when OFF.
Lr2 LED ring turns Red when comparator 2 is ON, and turn Blue or Green when OFF.
(Feature is only available for 2 comparator output option)
Lr3 LED ring turns Red when comparator 1 or 2 is ON, and turns Blue or Green when OFF.
(Feature is only available for 2 comparator output option)
(LED Ring: Blue when OFF: NPN output selected. Green when OFF: PNP output selected)
MODE
Press 3 sec.
or longer
After 1 second
(n ~ P
Message displayed
After 1 second
OP(
Message displayed
After 1 second
f;l
Message displayed
After 1 second
e(O
e(O
Message Display
After 1 second
lRg
L
Message Display
After 1 second
u
UN;
Message Display
Display Scaling
Decimal Point Position
MODE
(Display Scaling)
Set Offset Value
MODE
(Display Scaling Set)
Full Scale Value
Only in Output Selection
Pressure when the
analog is at zero point
MODE
Pressure when the
analog is at span point
kY5
kY5
Current setting
Hysteresis
npn
npn
Current unit
NPN output
setpoint
f-0
f-1
Filter off
Current setting
f-3
Time constant 2.5s
eOf
EoF
Current Setting
Power-save OFF
Lr0
No LED interlock
lRI
Lr3
Current Setting
Comparator 1 & 2 are
interlocked with LED
P5I
ET[
Current Setting
psi, bar or mPa
D IS PL AY SE T TI NG
After 1 second
d-p
d
0. 0 0
Message Display
Current Setting
After 1 second
d-l
d
0. 0 0
Message Display
Current Setting
After 1 second
d
d-K
0. 0 0
Message Display
Current Setting
ANALOG O UP U T SCALI NG
After 1 second
A-L
a
0. 0
Message Display
Current Setting
After 1 second
a
a-k
100. 0
Message Display
Current Setting
11
Select with
X W
keys
!;n
Window comparator
Select with
X W
keys
pnp
PNP output
X W
Select with
keys
f-1
f-2
Time constant 25ms
Time constant 250ms
f-4
f-5
Time constant 5s
Time constant 10s
Select with
X W
keys
Eon
Power-save ON
Select with
X W
keys
Lr1
Comparator 1 is
interlocked with LED
Lr2
Comparator 2 is
interlocked with LED
Select with
X W
keys
P5I
Display Scaling
X W
Select with
keys
0
0. 0
0. 0 00
0. 0 0
X W
Key to Select Between
(–)1999~(+)9999
X W
Key to Select Between
(–)1999~(+)9999
Set Any Desired Position Within the
X W
–100 to 150% range with the
Set Any Desired Position Within the
X W
–100 to 150% range with the
keys
keys