Useful tips & recommendations
Once your appliance has been fitted, the following recommendations are made to ensure
you enjoy the best results from your purchase;
1
The installation of this appliance must have been carried out by a qualified installer and
in accordance with all local laws and regulations.
2
The chimney must be swept before the appliance is installed and checked annually to
ensure continued clearance of combustion products and that there is no excessive build-
up of soot.
3
The glass door and the upper part of the decorative frame are considered to be a
working surfaces and as such will become hot when in use. Care should be exercised
when using the controls of the appliance when it is hot. We also recommend that a
fireguard be fitted for the protection of young children, the elderly or infirm.
4
When new any ceramic components may produce a slight odour, but this will completely
vanish after a few hours of use.
5
The appliance MUST NOT be used with the door open or with the glass panel removed.
If there is any suspicion of damage to the glass the appliance must not be used.
6
Check periodically that any purpose-made ventilation is free from obstruction.
7
To obtain the best results from your fire we recommend that it be serviced annually.
8
These instructions are provided to assist you to operate the fire correctly and should be
kept in a safe place.
9
If you have any reason to suspect a gas leak, turn off the appliance at the isolating point
and contact your installer.
10
This appliance is fitted with a flue blockage device that will shut off the appliance in the
event of abnormal flue conditions. If this device repeatedly shuts off the appliance your
installer should be informed and the cause rectified. This device is NOT a substitute for
an independently mounted carbon monoxide detector.
11
Curtains should not be hung above the appliance.

Operation of the fire

1
It should be noted that your fire is fitted with a Flame Supervision Device, which cuts off
the gas supply to your fire if, for any reason the pilot light is extinguished. The pilot flame
heats the thermocouple probe and allows gas to flow to the burners. If due to pilot failure,
the thermocouple cools, no gas will flow to the main burner. If the fire is turned off or the
flames go out, wait for AT LEAST 3 MINUTES before attempting to relight the fire.
2
The power supply to the appliance should be left on at all times as the appliance is fitted
with a fan to increase the circulation of convicted air. The fan will operate when the
interior temperature has reached approximately 50ºC. The fan has two speed settings
which are controlled by a switch located beside the gas control. The lowest position is
slow and the upper position is fast. The fan may be run at whatever speed the user finds
most appropriate. Once the fire has been switched off, the fan will continue to run until
the interior temperature reduces to 37ºC. The fire is to be used with the circulation fan
turned ON. The control knob should be set to MIN to avoid the appliance overheating.
10