ACR STOVES Woodpecker WP5Q-P Manual técnico - Página 10

Navegue en línea o descargue pdf Manual técnico para Estufa de leña ACR STOVES Woodpecker WP5Q-P. ACR STOVES Woodpecker WP5Q-P 18 páginas.

Operation with door left open
Operation with the door open can cause
excess smoke and overfiring of the
appliance. The appliance must not be
operated with the appliance door left
open except as directed in the
instructions.
Dampers left open
Operation with the air controls or
appliance dampers open can cause
excess heat within the appliance. The
appliance must not be operated with air
controls, appliance dampers or door left
open except as directed in the
instructions.
Never leave the stove
unattended until the new
fuel is well alight.
Persistent fume emission is
dangerous and must be
investigated
.
If fume emission persists, open doors
and windows to ventilate the room and
let the fire die out. Have the chimney
inspected for blockages and clean if
required. Do not relight the fire until the
cause has been found. We recommend
that you seek professional advice.
This appliance has been designed to be
burned with the door closed at all times
other than when refuelling.
It should not be operated as an open
fire.
• Typical refuelling intervals for wood is
1 hour.
• Typical refuelling time for Smokeless
fuel is 1.5 hours.
18 of 32

Maintenance

We recommend that the appliance is serviced
annually by a competent engineer to ensure it's
continued safe operation.
Daily Maintenance
• The grate should be cleaned regularly
and the ash pan emptied daily.
Never allow the ash in the ashpan to
overfill allowing ash to be in contact
with the underside of the grate.
This will overheat the grate and cause
premature wear and distortion.
• The glass can be cleaned using a soft
damp cloth or a stove glass cleaner
(ACR Glassbright cleaner is available
from your local ACR stockist).
• Do not clean the glass of your stove
with abrasive cleaners or scratch pads
as this may damage the surface of the
glass causing it to weaken.
• Never allow the door gasket to
become wet when cleaning the glass,
this will deteriorate the gasket
prematurely.
Periodic Maintenance
• The chimney should be swept at least
once a year together with the flue pipe
connection. Care should be taken to
ensure that there is not a build up of
soot on the baffle and in the airways of
the appliance.
• If the appliance has not been operated
for long periods, the flue should be
inspected and swept before use to
ensure there are no blockages within
the flue.
• The internal vermiculite panels of the
appliance should be checked regularly
for soundness. If any wear and tear is
found, we recommend these parts are
replaced immediately.
• Check the rope door seals are intact
and are not worn. These should be
replaced on an annual basis to ensure
the correct operation of this appliance.
• Is advisable as part on the periodic
maintenance of your appliance to
lubricate the moving parts of your
stove i.e. handle, air control, door
hinges with a suitable high
temperature dry lubricant (i.e. micro-
fine graphite powder) this will ensure
the correct operation of your
appliance.
• It may be necessary to adjust to
tension of the door closing mechanism
during the lifetime of the appliance as
the sealing rope will compress over
time, this is achieved by the adjusting
the bracket on the body of the stove
to the required tension.
Summer
• When the stove is not going to be
used for long periods e.g. the summer
months, we recommend that you keep
the air slides fully open and the door
slightly ajar if possible. This will help to
prevent condensation which may in
turn lead to internal corrosion of
component parts.
19 of 32