American Standard SELECTRONIC 605XTMV Instrucciones de instalación - Página 3

Navegue en línea o descargue pdf Instrucciones de instalación para Termostato American Standard SELECTRONIC 605XTMV. American Standard SELECTRONIC 605XTMV 5 páginas. Thermostatic mixing valve

American Standard SELECTRONIC 605XTMV Instrucciones de instalación

INSTALLATION

MOUNT ENCLOSURE; Fig. 3
1
1. Remove the bottom SUPPLY HOSE (1) from the
SELECTRONIC ENCLOSURE (2). Fig. 3
2. Remove BOTTOM PLUG (3) from SELECTRONIC
ENCLOSURE (2). Fig. 3
3. Remove 4 screws from MIXER ENCLOSURE
COVER (2) and pull off COVER (2). Fig. 3b
4. Remove MIXING VALVE (7) from ENCLOSURE (3).
5. Install MIXER ENCLOSURE (4) under SELECTRONIC
ENCLOSURE (2) as shown in Fig. (3a). Hold the MIXER
ENCLOSURE (4) in that location and mark the four
mounting hole locations as shown. Fig. (3a)
NOTE: MIXER ENCLOSURE SUPPLY HOSES are
20" long. Distance between wall valves and MIXER
ENCLOSURE (4) must be taken into consideration.
5. The ENCLOSURE (4) works best if secured to a wall
stud or cross brace within the wall, using the SCREWS
(5) supplied. If the MIXER ENCLOSURE (4) is to be
installed on a tile or plaster wall the ANCHORS (6) and
SCREWS (5) should be used.
6. For installations on drywall or tiled walls; use
ANCHORS (6) and SCREWS (5) for securing MIXER
ENCLOSURE (4) to finished wall. Drill four 1/4" dia.
holes a minimum of 1-3/4" deep. Insert the four
ANCHORS (6) flush with face of the finished wall.
Align the MIXER ENCLOSURE (4) and Install the
MOUNTING SCREWS (5). Tighten to secure MIXER
ENCLOSURE (4) to mounting surface.
CONNECT MIXING VALVE; Fig. 4
2
1. Install MIXING VALVE (1) back into ENCLOSURE.
2. Install FIBER SEAL WASHER (4) on MIXING
VALVE NIPPLE (3). Hold MIXING VALVE (1) in place
with one hand and with your other hand thread
SWIVEL NUT (2) onto MIXING VALVE NIPPLE (3).
Fig. 4. Use an adjustable wrench to tighten SWIVEL
NUT (2). Fig. 4a
3. Replace ENCLOSURE COVER and tighten securely.
CONNECT MIXING VALVE TO
3
WATER SUPPLIES; Fig. 5
1. Turn off hot and cold water supplies before
beginning.
2. Connect FLEXIBLE SUPPLIES (1, 2) directly to wall
supplies. Connection on MIXER supplies are 3/8"
compression. Connect left supply to Hot and right
supply to Cold wall supply. Use adjustable wrench to
tighten connections. Do not over tighten. FIG. 5
3. Faucet supplies measure 20" from the bottom of the
ENCLOSURE (3) base.
Note: If additional supply length is required, installer
must purchase parts separately.
Important: If SUPPLY HOSES (1, 2) are too long, loop
as to avoid kinking.
Fig. 3
SUPPLIES
3
WASTE
Fig. 3b
MOUNTING HOLES
6
4
5
ILLUSTRATION SHOWN
LESS MIXING VALVE
Fig. 4
4
2
3
1
Fig. 5
WALL SUPPLIES
HOT
1
2
LAVATORY RIM OR
MOUNTING SURFACE
Fig. 3a
2
1
4-1/4"
(108mm)
ENCLOSURE
MOUNTING
HOLES
1-3/16"
(46mm)
4
2
7
ADJUSTABLE
Fig. 4a
WRENCH
2
COLD
2
3