ADJUST TEMPERATURE

TO ADJUST TEMPERATURE;
4
Fig. 6
1. Adjust temperature by inserting a 4mm Hex Wrench
into hex opening in the side of enclosure. Fig. 6.
2. To decrease temperature, rotate up. (clock-wise)
3. To increase temperature, rotate down. (counter-
clockwise)
SERVICE
TO SERVICE CARTRIDGE; Fig; 7
5
1. Turn off water supply.
2. Remove MIXING VALVE ENCLOSURE COVER.
3. Disconnect MIXING VALVE (1) from SELECTRONIC
ENCLOSURE (2). Fig. 7.
4. Pull MIXING VALVE (1) out from ENCLOSURE (5).
If SUPPLY HOSES (3) are not long enough to gain
access to TEMPERATURE CALIBRATION UNIT (6)
&THERMOSTATIC CARTRIDGE (4) disconnect
SUPPLY HOSES (3) from wall valves. Fig. 7a.
5. Rotate the BLACK CLAMP (7) with your finger and
pull off the TEMPERATURE CALIBRATION UNIT (6).
Fig 7b, 7c.
6. Use a adjustable wrench to unthread
THERMOSTATIC CARTRIDGE (4) from housing. Fig. 7d.
7. Remove THERMOSTATIC CARTRIDGE (4). Fig. 7e.
8. Rinse clean any debris from SCREENS (8) and
inspect O-RINGS (9) for damage. Replace O-RINGS (9)
if any damage is found. Fig. 7f.
9. Reverse above steps and reassemble MIXING
VALVE (1). Assemble MIXING VALVE (1) to
SELECTRONIC ENCLOSURE (2).
10. Assembly ENCLOSURE COVER and tighten
securley.
Fig. 6
TO DECREASE
TEMPERATURE
Fig. 7
1
Fig. 7b
7
Fig. 7d
Fig. 7d
Fig. 7f
9
3
TO INCREASE
TEMPERATURE
Fig. 7a
Fig. 7a
2
1
5
3
Fig. 7c
Fig. 7e
Fig. 7e
4
8
4mm HEX
WRENCH
6, 4
6
4
4