Door-Gard 232iLM Instrucciones de instalación y programación - Página 6

Navegue en línea o descargue pdf Instrucciones de instalación y programación para Sistema de interfono Door-Gard 232iLM. Door-Gard 232iLM 8 páginas. Keypad

Programming the 232iLM Keypad
The SSWiLM keypad has it's own local programming options. All user codes and other access control features are
programmed into the controller. Refer the Self-Contained Access Control Programming Guide for those features. The
programming options chart below shows all the programming commands available in the SSWiLM.
To program the SSWiLM you fi rst must enter program mode.
To enter program mode enter the following on the keypad: 099 # program code ✱ (default program code is 6789).
Keypad Default Settings
Option
Local Program Code
Visual Keypress Feedback Enabled
Keypad Illumination
Programming Options Chart
Command/Action
Command 90
Change Local Program Code
Command 91
Set/Clear Keypad Options
(options below, defaults in bold)
Option
0 – Visual Keypress Feedback
1 – Audio Keypress Feedback
11 – Keypad Illumination
12 – Keypad Dimming
13 – Door Bell Select
Command 92
Set Door Bell Duration
Command 96
Reset Keypad to Default Settings
Exit Program Mode
Testing the Keypad
After installing the keypad, it is recommended that you perform the keypad self-test once a year, to ensure that the keypad
is working properly.
To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890 # 123456 ✱
If all 12 keypresses are accepted, the keypad enters self-test mode.
The LEDs alternate three times followed by the sounder beeping three times.
When fi nished the yellow LED starts fl ickering rapidly.
Press ✱ to clear.
6
Default Setting
6789
Enabled
Keys to Enter/Details
90 # 0 # 0 # new code ✱ new code ✱ (default = 6789)
91 # option # set/clear # ✱ ✱
Clear
0 = Disabled
0 = Disabled
0 = Disabled
0 = Disabled (always bright)
0 = Disabled
92 # 4 # time # ✱ ✱
92 # 4 # 0 # ✱ ✱
96 # 0 # 0 # ✱ ✱
Press the ✱ Key
232iLM Keypad Installation & Programming
Option
Audio Keypress Feedback Enabled
Door Bell Select
Keypad Dimming
Set
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled
Set timed output (1 – 99 seconds)
Set to continuous
Default Setting
Continuous
Enabled
6-050800 X2