CONDUCTOR CAVITY
1. Close the tool handles fully, and hold
them firmly closed.
2. Insert the appropriately sized GO gage
(Green) member under the locator and
into the conductor cavity, of the die
(Red or Blue) you are trying to gage
(See Figure 2).
3. The GO gage member should freely enter
the die.
______________________________________________________________________________________________
TI4001
ASTRO TOOL CORP.
CONNECTOR ASSEMBLY TOOLING
GAGE MEMBER
CAUTION: DO NOT CRIMP THE GAGE MEMBER.
DOING SO MAY SERIOUSLY DAMAGE THE DIE SET!
©2009 Astro Tool Corp
21615 SW T-V Hwy, Beaverton, OR 97006 USA
Phone: 503-642-9853 Fax: 503-591-7766
4. Attempt to insert the NO-GO gage (Red)
member under the locator and into the
conductor cavity, of the die (Red or Blue)
you are trying to gage (See Figure 2).
5. The NO-GO gage (Red) member may
enter slightly into the die cavity, but should
not pass fully through the cavity. If the
NO-GO gage (Red) member does enter the
cavity fully, the die is worn and should be
replaced.
UPPER DIE
LOCATOR
LOWER DIE
FIGURE 2
Page 4 of 6
Astro Tool Corporation
REV. A
7-9-08