Dotronix DOT-X Series Manual del usuario - Página 11

Navegue en línea o descargue pdf Manual del usuario para Mando a distancia Dotronix DOT-X Series. Dotronix DOT-X Series 12 páginas. Handheld addressable remote controls

CUSTOM OPTIONS
PROGRAMMING ON/OFF TIMER * (Not available on the 20)
In some installations it will be desirable for the monitor(s) to turn on an
off at the same time each day. The programmable ON/OFF timer
provides this function.
As shipped from the factory, the ON/OFF timer is not active. To activate
the ON/Off timer, select ON/OFF timer on the selection menu and press
the right arrow key until the word "ENABLED" appears. If the ON/OFF
timer is not activated, the timer can be programmed as described below,
but the ON/OFF action will not occur until the ON/OFF function is
activated.
The ON/OFF timer depends on the monitor clock. If the clock is not set
properly or is not operating, the ON/OFF timer will not work properly. To
set the monitor clock, refer to earlier section titled SETTING THE CLOCK.
To set the ON/OFF time, first it is necessary to enter the security
code and unit number, refer to GETTING STARTED earlier in this
manual for the procedures to enter the security code and unit number.
Then press and hold the TIMER key or 6 key until the following
screen appears (typically 6 – 8 seconds).
KEY NEW START TIME
_8:30
THEN PRESS ENTER KEY
KEY NEW STOP TIME
16:15
THEN PRESS ENTER KEY
The times displayed are the current Start and Stop times and may be
any value from 0:00 to 23:59.
To change the times, key in the new Start time. Notice that as the
numbers are keyed in they move from left to right until all four digits have
been entered.
Some digits are not accepted. For example numbers larger than 2 that will be in the first
digit position are not accepted, numbers larger than 4 are not accepted for the second digit
and numbers larger than 5 are not accepted for the third digit.
13
SECURITY CODE
Jumper
Location
DOT-X Series HARC module
Jumper
Pins disconnected
location
(Factory setting)
J4
Security Active
Jumper J4 will de-activate security when it is placed in the position to
connect the pins of J4. Some installations do not require security and
this option may be used in those cases. This option is also useful to
temporarily bypass security in case the security code is lost.
Jumper J5 is for factory use only and should never be installed.
Pins connected
No Security
10