To adjust the sensor to get a blocking of approximately 50 % do the following:
• Make a bracket that enables the sensor to be moved sideways, or order one from
Baumer. Specify type of conveyor!
• Set the sensor in Gripper Pulse Mode, see chapter 6.4
• Watch the Output LED during production. It should be flashing.
The next step can be dangerous! Watch your hands if you do the movement during
run!
• Move the sensor sideways until the Output LED is ON for approximately as long as it is
OFF to get 50 % duty cycle.
• You can also check with a scope, either on the Output directly or between TP8 and
TP1, see chapter 6.
If this is done OK, the sensor will only count one edge for half a Gripper, which will be the
ideal situation.
User Manual DENEX Gripper LED
Version 2013-02, V1.4
12/24
www.baumer.com
Baumer Electric AG
Frauenfeld, Switzerland