Baumer O200 Manual de instrucciones - Página 25

Navegue en línea o descargue pdf Manual de instrucciones para Accesorios Baumer O200. Baumer O200 34 páginas. Sensors with io-link

Baumer O200 Manual de instrucciones

4.7 Quality Parameters

The O200 sensors offers quality values to give an idea about the reliability or trend of the process based on
the ratio of the current signal and the threshold or minimum required signal.
Contamination indicaton
-
Alignment indication
-
Evaluation of process reliability
-
Parameter
Short Description
name
Quality Value
Same value as described in section 4.2.1.
The quality value represents the excess gain ration in %
100 = Exactly the amount of light needed for a switching
operation
200 = Twice the amount of light needed
O200.G, O200.S:
Quality = Strength of received light / Strength required
O200.R:
Quality = Intensity value / SSC1 SP1
Quality Bit
Sets the threshold for the quality bit value in % which is
Threshold
mapped to the process data in (section 3.2.1)
The quality bit is directly connected to the weak signal
indication LED (section 4.6.2)
Default: 150

4.8 Device Access Locks

Parameter name
Parameter (write) Access
Lock
Data Storage Lock
Parametrization Lock
Local User Interface Lock
en_BA_O200_IO-Link_V1.docx
15.08.2018/
Short Description
n/a
Deactivates the parameter server
functionality / does not overtake values
n/a
n/a
25/34
Rights
Unit /
Allowed
values
ro
rw
Rights
Unit /
Allowed
values
True/False
rw
True/False
rw
rw
True/False
rw
True/False
Baumer Electric AG