Baumer HUBNER BERLIN PROFI NET microGen HMG10P Instrucciones de montaje y funcionamiento - Página 18
Navegue en línea o descargue pdf Instrucciones de montaje y funcionamiento para Media Converter Baumer HUBNER BERLIN PROFI NET microGen HMG10P. Baumer HUBNER BERLIN PROFI NET microGen HMG10P 40 páginas. Incremental encoder with magnetic sensing
También para Baumer HUBNER BERLIN PROFI NET microGen HMG10P: Instrucciones de montaje y funcionamiento (32 páginas), Manual de instrucciones (44 páginas)
MOUNTING / HOW TO PREVENT MEASUREMENT ERRORS
4.5
How to prevent measurement errors
To ensure that the device operates correctly, it is necessary to mount it accurately as de-
scribed in section 4�1 to 4�4, which includes correct mounting of the torque arm�
The radial runout of the drive shaft should not exceed 0�2 mm (0�03 mm recommended),
to prevent an angle error�
An angle error may be reduced by increasing the length of L1
L2 of the torque arm, see below, is at least equal to L1
The angle error Δρ
Δρ
= ±90°/π · R/L1
mech
with R: Radial runout in mm
L1:
Example of calculation:
For R = 0.06 mm and L1 = 69.5 mm the resulting angle error Δρ
i
For more information, call the telephone hotline at +49 (0)30 69003-111
For this different support plates for the torque arm are available on request�
1)
If L2 < L1, L2 must be used in the calculation formula�
2)
18/40
can be calculated as follows:
mech
Distance of the torque arm to the center point of the device in mm
MB258EN - 11196411, 21A1, Baumer_HMG10-Inc_EN_202103_MI_11196411
2)
L1
� Make sure that the length
1)
�
equals ±0�025°�
mech