Main connector
Scatec-1x
11.7 Optical data
Laser
Wavelength
Pulse frequency
Duty cycle
Average power
Laser class
Beam dimensions
at emission point
Scatec-10:
Scatec-15:
Focus position
Scatec-10:
Scatec-15:
Optical receiver
11.8 Application data
Measuring range
Scatec-10:
Scatec-15:
Mounting height
Scatec-10:
Scatec-15:
Object speed
Minimum object spacing
Counting rate
Product orientation
Output pulse length
Sensitivity
User manual Scatec-10 / -15
Version 2017-10
Control unit
when mounting the Sactec)
into the Scatec.
Low-impedance
control unit's ground and the Scatec ground sufficiently low.
interconnection
645 nm - 670 nm (visible red)
50 kHz
50%
< 1.0 mW
2 (to IEC 60825-1 / 2014)
about 2.5 x 4.0 mm
70 mm beneath sensor
100 mm beneath sensor
70 mm beneath sensor
100 mm beneath sensor
equipped with near infrared suppression and daylight suppression filter
0 to 90 mm beneath sensor
0 to 120 mm beneath sensor
70 mm
100 mm
2 m/s maximum (5 m/s maximum for thicker edges)
10 mm @ v = 1 m/s and output pulse length 10 ms, or proportional to the
speed and output pulse length
1.5 million maximum copies/h (@ 2 ms output pulse length and 0 ms dead
time)
Folded or cut edge facing laser beam
0.2 ... 100 ms adjustable
www.baumer.com
Scatec housing is grounded (use teeth lock washers
Cable shield properly grounded at the controller end
Cable shield properly attached to the connector plugging
Keep the impedance of the interconnection between the
Line focus, 6 mm long
Line focus, 8 mm long
36 / 44
Baumer Electric AG