Baumer NE210 Manual de instrucciones - Página 36

Navegue en línea o descargue pdf Manual de instrucciones para Caja Baumer NE210. Baumer NE210 44 páginas. Electronic preset electronic preset counter

Baumer NE210 Manual de instrucciones
NE210
Line 1
Line 2
Line 3
Line 4
36
Programming field PRO 0
Here it is possible to select and modify all operation parameters.
The operation parameters that are disabled for the operator are also
displayed.
Press the key
again
Current counter status
Preset value
Scaling factor
Programming field PRO 1
All functions and vaules conditioned by the machinery are program-
med here. In programming field PRO 1, 12 programming lines are
displayed in succession.
Default settings are always printed with *.
Decimal point
0 * 99999
1
9999.9
2
999.99
3
99.999
Pulse signal time in seconds (s); adjustable from 0.02 s to 9.99 s
0.00
no output signal
* 0.25 s
0.02...9.99 s
● DIP-switch 2 activates pulse contact of continuous contact.
Counting mode (see 5.1)
0 * Track A and UP / DOWN signal on track B
1
Track A and STOP signal on track B
2
Differential counting, track A adding, track B subtracting (A-B)
3
Totalizing, tracks A and B adding (A+B)
4
Track A 90° B, single evaluation
5
Track A 90° B, twofold evaluation
6
Track A 90° B, fourfold evaluation
(counting frequence max. 5 kHz)
7
Time counter with preset
8
Time delay relay function
Accept preset value
0 * In the case of automatic, external or manual reset
1
Effective immediately with
www.baumer.com
acknowledgement.