Amphenol Temposonics MH Series Manual del usuario - Página 11
Navegue en línea o descargue pdf Manual del usuario para Accesorios Amphenol Temposonics MH Series. Amphenol Temposonics MH Series 12 páginas. Analogue/pwm tester
También para Amphenol Temposonics MH Series: Manual de instrucciones (18 páginas)
3. Operations (continued)
3.3 Verification
Verify the sensor is reading the displacement of the magnet by moving the
magnet in the bench test of the attached sensor or by stroking the cylinder.
Observe the change in output reading.
3.4 Troubleshooting
No Power
1. Confirm the power switch is in 'ON' position
2. M-Series Tester my be in Low Power Mode
3. Plug in AC Power adapter and check the battery level
The sensor readings aren't showing on the display
1. Is the M-Series Tester in the correct mode?
2. Ìs the M-Series battery level above 9 Vdc?
3. Is the sensor connected to the appropriate terminals?
Error Message '[--]' is seen in PWM od PWM TOF mode
1. Make sure the correct plug is in the PWM port at the top of the M-Serie Tester
2. If in TOF mode, make sure the correct number or recirculations is selected
3. Check battery level to ensure the unit is providing a minimum of 9 Vdc to sensor
Note:
The M-Series Tester is not a calibrated device and should only be used for indi-
cation purpose only. The M-Series Tester is designed to be used to verify that
the sensor is functional after cylinder assembly and as a field troubleshooting
device. For field troubleshooting the tester is designed to isolate the sensor
from the rest of the vehicle in order to independently verify sensor functionality.
I
11
I
M-Series Tester
User's Manual
MTS Sensors