should only be installed on vertical surfaces or in the ground 
at a minimum distance 0.5 m from the illuminated object  Do 
not look directly into the floodlight while it's lighting.
  1. Before starting the assembly, disconnect the mains supply. 
  2. Screw the floodlight to the wall or ground.
  3. Connect power supply wires to the appropriate wiring in 
the floodlight. It is recommended to use airtight cans and 
electrical connection cords.
 red wire – phase (L)
 blue wire – neutral (N)
 green / yellow wire – ground (PE)
  4. Secure the power cable for the floodlight.
  5. Set the beam angle and tighten the retaining screws.
6