7. Start burner

1.
Check that the cooling air hose and gas hose are properly and securely connected.
2.
After reversal, open the gas manual ball valve on down comer on the firing side.
3.
Open the corresponding gas flow control valve to establish the gas flow.
4.
For the same port burner, an average flow or a satisfactory flow distribution ratio can
be obtained by adjusting the needle valve opening.
Cooling air
connection
Gas connection

8. Flame Adjustment

8.1
Flame length adjustment
1.
When the gas flow reaches the normal flow, the flame length can be adjusted
through the flame length adjustment knob.
2.
As shown in Figure 5, FVR (Flow Velocity Regulator) is used for flame length
adjustment. Rotate the FVR counterclockwise, the gas velocity increases, and the
flame becomes shorter; rotate the FVR clockwise, the gas velocity becomes slower,
and the flame becomes longer.
3.
On the adjustment mechanism, there is a scale with an engraved line, and the
positions are marked as 1-5. Position 1 is fully rotated clockwise, the shortest flame,
and position 5 is fully rotated counterclockwise, and the longest flame.
8.2
Energy release position adjustment
1.
After the flame length is adjusted, the energy release position can be adjusted
through the FDR (Flow Distribution Regulator adjustment knob).
2.
There is an angle scale marked on the FDR disc, when the FDR rotates, the gas flow
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions –FFA10 Burner Operation Manual
Figure 4: Flex Fire
burner connections
®
10