Anderson FFA10 Manual de instrucciones - Página 12

Navegue en línea o descargue pdf Manual de instrucciones para Quemador Anderson FFA10. Anderson FFA10 13 páginas.

3.
Clean the seal plate
10.2 Smoky flame
1.
Gas rich-reduce gas flow
2.
Lean air-increase combustion air flow
3.
Debris block the burner tip-take out burner and clean
4.
Built-up particles inside burner block-take out burner and clean
10.3 Flame too long
1.
Keep the gas pressure at 30-500mbar
2.
Reduce the gas flow so that the single burner is within the rated flow range, see
the technical data sheet
3.
Increase the gas velocity and reduce the flame length through the flame length
adjustment mechanism
4.
Poor mixing, adjust the flame angle upward
10.4 Flame too short
1.
Maintain gas pressure and increase gas flow
2.
Reduce the gas velocity and extend the flame length through the flame length
adjustment mechanism
3.
Mixing too fast, adjust the flame angle downward
11.

Maintenance and cautious

11.1 Dismantle burner for maintenance
1.
Loosen the inner gas gun lock nut
2.
Loosen the packing nut
3.
Pull out the inner tube assembly of the front section of the burner
4.
Removing the inner nozzle
5.
Removing the outer nozzle
11.2 Cleaning the inner nozzle, outer nozzle and gas gun assembly
11.3 Precautions when reassembling
1.
Inspect the outer nozzle seal and packing, and replace if damaged
2.
It is also possible to remove the inner and outer nozzles separately without
removing the burner
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions –FFA10 Burner Operation Manual