2.3  Dimensions, Weight and Capacity.
Width :
Length :
Height :
Total weight:
Tires :
Option pneus :
The boom capacity : Our loader has been tested to lift and move a load of 1100 lbs with the boom at full
extension, and the load at the end of the lifting arm. The hydraulic pressure for this operation represents
2450 PSI
2.4  Optional Equipment
2.4.1  The optional hydraulic power unit. This unit is
installed at the front of the trailer, behind the protection grid. A
pressure valve maintains the oil pressure at 2450 PSI and this
SETTING must never be modified. Always maintain the hydraulic oil
level of your machine at 3 inches (7.5cm) from the oil cap. You must
always use Hydraulic Oil #32.
2.4.2  Optional #400 Winch : You can add a hydraulic winch close to the mast on the boom. You will
only need to bolt it in place using the predrilled holes. A pulley support is
installed a little further on the boom. The purpose of this winch is to pull
loads from further away than the grapple can reach, using the 100 feet
(30.3m) length of the steel cable.
An auxiliary valve is supplied and installed at the front of the
control valve assembly. If the loader has been already installed with an
auxiliary valve (a tandem hydraulic lever for example) a double auxiliary
valve will be required because 2 individual auxiliary valves cannot be
installed on the same control valve assembly.
2  Loader M-115 General Characteristics (2
65 po
(1,65 m)
17 ft
(5.28 m)
7 ft 6 in
(2,28 m)
2264 lbs
(1029 kg)
11L-15 /10 pLys
12.5L-15 /10 pLys
:
nd
(Without a load and the grapple stabilized on the central beam)
(Excluding all options except the hydraulic power unit)
Tire pressure :
Tire pressure :
part).
55 psi (376 kpa)
60 psi (410 kpa)
Install on trailer