Andrew 400BPDM-C Instrucciones de instalación
Navegue en línea o descargue pdf Instrucciones de instalación para Cables y conectores Andrew 400BPDM-C. Andrew 400BPDM-C 2 páginas. Connector attachment
Connector Attachment
For Braided Cable CNT-400
Din Male, Captivated Pin, Clamp-type Body
Connector: 400BPDM-C
Connector Body
1.
Straighten first 200.0 mm (7.874") min.
of the cable.
200 mm (7.874") min.
4.
Remove 5.0 mm (0.197") of foil & foam,
exposing the center conductor.
Remove all foam/glue residue from the
center conductor.
Don't damage center conductor
5.0± 0.5 mm
(0.197± 0.020")
6.
Fold back braid around part A and comb braid as shown,
the braid should be straight and equally spaced after comb.
Clear all residual braid wire
Tools
A
Cable Attachment
2.
Remove 6.5 mm (0.256") of Jacket only.
5.
Taper braid towards center conductor as shown;
According to illustration below to push and rotate slightly part A onto cable without
damaging the braid.
7.
Bulletin 7677441
Andrew Institute offers installation training.
Safety
Wire
File
Knife
Brush
3.
Comb braid straight with wire brush;
Fold back braid as shown.
6.5± 0.5 mm
(0.256± 0.020")
Cut off the redundant braid as shown.
Revision A
Page 1 of 2
16 mm
16 mm
Torque
Diagonal
Wrench
Wrench
Pliers