Daikin Altherma 3 R F Manual de referencia del usuario - Página 17

Navegue en línea o descargue pdf Manual de referencia del usuario para Climatizadores Daikin Altherma 3 R F. Daikin Altherma 3 R F 20 páginas.
También para Daikin Altherma 3 R F: Manual de instrucciones (12 páginas), Manual de instrucciones (16 páginas), Manual de instrucciones (16 páginas), Manual de instalación (12 páginas)

Daikin Altherma 3 R F Manual de referencia del usuario
4.10
Installer settings: Tables to be
filled in by installer
4.10.1

Configuration wizard

Setting
System
Indoor unit type (read only)
Backup heater type [9.3.1]
Domestic hot water [9.2.1]
Emergency [9.5]
Number of zones [4.4]
Backup heater
Voltage [9.3.2]
Configuration [9.3.3]
Capacity step 1 [9.3.4]
Additional capacity step 2
[9.3.5] (if applicable)
Main zone
Emitter type [2.7]
Control [2.9]
Setpoint mode [2.4]
Schedule [2.1]
Additional zone (only if [4.4] = 1)
Emitter type [3.7]
Control (read only) [3.9]
Setpoint mode [3.4]
Schedule [3.1]
Tank
Heat up mode [5.6]
Comfort setpoint [5.2]
Eco setpoint [5.3]
Reheat setpoint [5.4]
4.10.2

Settings menu

Setting
Main zone
Thermostat type [2.A]
Additional zone (if applicable)
Thermostat type [3.A]
Information
Dealer information [8.3]
5

Energy saving tips

Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ
Daikin Altherma 3 R F
4P495251-1B – 2019.06
▪ Use a weekly schedule for your normal space heating needs. If
necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room
temperature until the next scheduled action. Example: When
you have a party, or when you are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode.
Fill in...
Tips about leaving water temperature
▪ In heating mode, a lower desired leaving water temperature
results in lower energy consumption and better performance.
▪ Set the desired leaving water temperature in accordance with the
heat emitter type. Example: Underfloor heating is designed for
lower leaving water temperature than radiators and heat  pump
convectors.
Tips about DHW tank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program to heat up the DHW tank to a preset value (Comfort =
higher DHW  tank temperature) during the night, because then
space heating demand is lower.
▪ If heating up the DHW  tank once at night is not sufficient,
program to additionally heat up the DHW tank to a preset value
(Eco = lower DHW tank temperature) during the day.
▪ Make sure the desired DHW  tank temperature is NOT too high.
Example: After installation, lower the DHW tank temperature daily
by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during
periods of the day when instant hot water is necessary. Example:
In the morning and evening.
6
6.1
The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.
As end user, you have to:
▪ Keep the area around the unit clean.
Fill in...
▪ Keep the user interface clean with a soft damp cloth. Do NOT use
any detergents.
Refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent
gases into the atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
5 Energy saving tips

Maintenance and service

Overview: Maintenance and
service
NOTICE
Applicable legislation on fluorinated greenhouse gases
requires that the refrigerant charge of the unit is indicated
both in weight and CO
equivalent.
2
Formula to calculate the quantity in CO2 equivalent
tonnes: GWP value of the refrigerant × total refrigerant
charge [in kg] / 1000
Please contact your installer for more information.
WARNING: FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
User reference guide
17