Daikin Altherma 3 R F Manual de referencia del usuario - Página 19
Navegue en línea o descargue pdf Manual de referencia del usuario para Climatizadores Daikin Altherma 3 R F. Daikin Altherma 3 R F 20 páginas.
También para Daikin Altherma 3 R F: Manual de instrucciones (12 páginas), Manual de instrucciones (16 páginas), Manual de instrucciones (16 páginas), Manual de instalación (12 páginas)
▪ When auto emergency is set to Automatic and a heat pump
failure occurs, the backup heater will automatically take over the
heat load and the domestic hot water production.
▪ When auto emergency is set to Manual and a heat pump failure
occurs, the domestic hot water and space heating operation will
stop and need to be recovered manually via the user interface. To
recover operation manually, go to the Malfunctioning main
menu screen, where the user interface will then ask you to confirm
whether the backup heater can take over the heat load or not.
When the heat pump fails,
interface.
Possible cause
Heat pump is damaged.
INFORMATION
When the backup heater takes over the heat load,
electricity consumption will be considerably higher.
7.6
Symptom: The system is making
gurgling noises after
commissioning
Possible cause
There is air in the system.
Various malfunctions.
(a)
We recommend to purge air with the air purge function of
the unit (to be performed by the installer). If you purge air
from the heat emitters or collectors, mind the following:
WARNING
Air purging heat emitters or collectors. Before you
purge air from heat emitters or collectors, check if
is displayed on the home screen of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room where you want to
purge air is sufficiently ventilated. Reason: Refrigerant
might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.
8
Relocation
8.1
Overview: Relocation
If you want to relocate parts of your system (user interface, indoor
unit, outdoor unit, DHW tank...), contact your installer. You can find
the contact/helpdesk number via the user interface.
EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ
Daikin Altherma 3 R F
4P495251-1B – 2019.06
or
will appear on the user
Corrective action
See
"7.1 To display the help text
in case of a malfunction" on
page 18.
Corrective action
(a)
Purge air from the system.
Check if
or
is displayed
on the home screen of the user
interface. See
"7.1 To display the
help text in case of a
malfunction" on page 18
for more
information about the
malfunction.
or
9
Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
10
Glossary
DHW = Domestic hot water
Hot water used, in any type of building, for domestic
purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the heat pump.
Dealer
Sales distributor for the product.
Authorised installer
Technical skilled person who is qualified to install the
product.
User
Person who is owner of the product and/or operates the
product.
Applicable legislation
All international, European, national and local directives,
laws, regulations and/or codes that are relevant and
applicable for a certain product or domain.
Service company
Qualified company which can perform or coordinate the
required service to the product.
Installation manual
Instruction manual specified for a certain product or
application, explaining how to install, configure and maintain
it.
Operation manual
Instruction manual specified for a certain product or
application, explaining how to operate it.
Accessories
Labels, manuals, information sheets and equipment that are
delivered with the product and that need to be installed
according
to
the
instructions
documentation.
Optional equipment
Equipment made or approved by Daikin that can be
combined with the product according to the instructions in
the accompanying documentation.
Field supply
Equipment NOT made by Daikin that can be combined with
the
product
according
accompanying documentation.
8 Relocation
in
the
accompanying
to
the
instructions
in
the
User reference guide
19