3M Litmann Quality 3100 Manual de instrucciones - Página 10

Navegue en línea o descargue pdf Manual de instrucciones para Equipamiento médico 3M Litmann Quality 3100. 3M Litmann Quality 3100 16 páginas. Mining cable splice kit
También para 3M Litmann Quality 3100: Manual de inicio rápido (2 páginas)

3M Litmann Quality 3100 Manual de instrucciones
7.0
Connect Phase Conductors
7.1
Join power conductors with proper connectors and appropriate crimping tool.
Make certain conductors butt center indents of connector.
8.0
Apply Primary Insulation
8.1
Apply one half-lapped layer of 3M
edge of taper to edge of taper.
NOTE: Scotch
Glass Cloth Tape 27, while not included, may be used at this time.
®
8.2
Apply half-lapped layers of two-thirds-stretched Scotch Linerless
Splicing Tape 130C (tacky side DOWN) over 1700P tape and up onto tapers.
Build up half-lapped layers of 130C tape until equal to or greater than original
and extending ½" (13 mm) onto existing insulation.
Figure 20
Temflex
Figure 21
1/8"
3 mm
Scotch
Tacky Side DOWN
Color coding
Figure 22
10
Vinyl Electrical Tape 1700P from
3M
Temflex
Electrical Vinyl Tape 1700P
1/8"
3 mm
Linerless Rubber Splicing Tape 130C
®
Rubber
®
Color coding
78-8127-6830-3-C