Connect Phase Conductors
7.1
Join power conductors with proper connectors and appropriate crimping tool.
Make certain conductors butt center indents of connector.
8.0
Apply Primary Insulation
8.1
Apply one half-lapped layer of 3M
edge of taper to edge of taper.
NOTE: Scotch
Glass Cloth Tape 27, while not included, may be used at this time.
®
8.2
Apply half-lapped layers of two-thirds-stretched Scotch Linerless
Splicing Tape 130C (tacky side DOWN) over 1700P tape and up onto tapers.
Build up half-lapped layers of 130C tape until equal to or greater than original
and extending ½" (13 mm) onto existing insulation.
Figure 20
Temflex
™
Figure 21
1/8"
3 mm
Scotch
Tacky Side DOWN
Color coding
Figure 22
10
Vinyl Electrical Tape 1700P from
™
3M
Temflex
Electrical Vinyl Tape 1700P
™
™
1/8"
3 mm
Linerless Rubber Splicing Tape 130C
®
Rubber
®
Color coding
78-8127-6830-3-C