Section 4: Testing and Troubleshooting

4.1 Testing the PC4850

Once the PC4850 is connected and programmed, test
each of its functions to make sure it is working correctly.
The PC4850 should work as described in section 3.1,
"How the PC4850 Works".

4.2 Troubleshooting

The PC4850 should work correctly without the need for
adjustments. However, if you encounter problems get-
ting the unit to work, you can try adjusting the following
controls on the PC4850 circuit board. To adjust these con-
trols, first, remove power from the PC4850 (AC and bat-
tery power), then use a small screwdriver to change the
appropriate setting.
LCD Contrast
If the LCD is hard to read, turn the control marked RV1
clockwise to increase the display contrast. To decrease
the display contrast, turn the control counter-clockwise.
"Beep" Volume
The PC4850 keypad beeps whenever a key is pressed.
You can adjust the volume of these beeps. To increase the
volume, turn the control marked RV2 clockwise. To
decrease the volume, turn the control counter-clockwise.
Microphone Volume
If users cannot hear visitors when they call using the
PC4850, turn the control marked RV3 clockwise to
increase the microphone sensitivity. To decrease the
microphone sensitivity, turn the control counter-clock-
wise.
Pulse Dial Sensitivity
If the PC4850 does not unlock the door when a user dials
9 using a pulse dial telephone, turn the control marked
RV4 clockwise or counter-clockwise 1/10 of a revolution,
until the door unlocks when 9 is dialed.
Speaker Volume
If visitors cannot hear the user they are calling on the
PC4850, turn the control marked RV5 clockwise to
increase the speaker sensitivity. To decrease the speaker
sensitivity, turn the control counter-clockwise.

4.3 "System is Busy. Please Wait" Message

Whenever the system displays this message, visitors will
not be able to call users using the PC4850, but users will
still be able to enter the building using their access codes.
Postal workers will also be able to enter if a postal lock
has been installed.
If this message is displayed, check for a Telephone Line
Trouble. This trouble will occur when the outgoing tele-
phone line is disconnected from one or more units, or if
the telephone line is out of service. When the telephone
line is restored, the PC4850 will work normally. This
message is also displayed when another PC4850 current
has the line.
9