DSC Power Series PC1616 PC1832 PC1864 System Manual
Duress Codes (Access Codes 33 & 34) - Duress codes 33 and 34 are standard User Codes that will
transmit the Duress Reporting Code whenever the code is entered to perform any function on the
system.
Note: Duress codes are not valid when entering [*][5], [*][6] or [*][8] sections. No codes can be
programmed as a duplicate of another code. Duress codes cannot be programmed as a duplicate or as a
"Code + 1".
User Code Attributes
The default attributes of a new code will be the attributes of the code used to enter [*][5] whether it is a
new code or an existing code being programmed. System Master (Code 40) has Partition Access for all
partitions, as well as Attributes 3-4 ON by default.
Note: These attributes are not changeable.
Inherent Attributes (all codes except installer and maintenance)
Arm/Disarm - Any Access Code with Partition Access enabled will be valid for arming and disarming that
partition.
Command Outputs([*][7][1], [*][7][2], [*][7][3], and [*][7][4]) - If these outputs require Access Code
entry, any Access Code with Partition Access will be valid for performing the [*][7][1-4][Access Code]
functions on that partition.
Programmable Attributes ([*][5][Master/Supervisor Code][9][Code]).
1. For Future Use
2. For Future Use
3. Zone Bypassing Enabled
4. ESCORT Access
5. Downlook Remote Trigger to Phone Number 1
6. Downlook Remote Trigger to Phone Number 2
7. Bell Squawk upon Arming/Disarming
8. One Time Use Code
Note: Attributes 5 and 6 cannot be enabled on the same access code.
Bell Squawk Attribute
This attribute is used to determine whether an access code should generate an arming/disarming Bell
Squawk upon entry of the code for Away arming. The Wireless Keys with access codes associated with
them may generate Arming/Disarming Bell squawks. If desired, this option may be used with codes that
are manually entered. Please contact your installer to have this programmed.
https://alpha.adt.com/help/61[11/12/2018 9:40:17 PM]