DSE RH Series Manual - Página 10

Navegue en línea o descargue pdf Manual para Cámara de seguridad DSE RH Series. DSE RH Series 12 páginas. Ip anpr cameras with ocr
También para DSE RH Series: Configuración (12 páginas)

DSE RH Series Manual
ANPR. MANUAL
RH SERIES - PLATE READING IP CAMERAS
Page:10

Advanced adjustments

If you are not satisfied with the basic settings, you can customize them. Enter the sensor
configuration, as seen previously, and activate the DEBUG mode and the SCHEMA2 which is used
in night shooting.
Below we explain the fundamental parameters that come into play in the recovery of the night
license plates
In the EXPOSURE folder you find the shutter speed which is recommended at 1/1000. You can set
it to shorter values, such as 1/2000 if you plan the passage of vehicles at high speed. The area
can be set to CENTER AREA or even CENTER SPOT if you want more brightness in the center.
The manual IR power mode is set in the DAYNIGHT folder at the factory. With the slider you can
adjust the power of the LEDs which is factory set to 40. The power is adjusted according to the
distance of the vehicle, but in general it must be kept rather low to prevent the plate from being
bleached at night. On close-ups the best result is obtained with very low values even from 2 to 5.
DSE SRL - ITALY - WWW.DSE.EU