DSP ULE Starter Kit Manual del usuario - Página 12
Navegue en línea o descargue pdf Manual del usuario para Hardware informático DSP ULE Starter Kit. DSP ULE Starter Kit 17 páginas.
4.4 Messages from ULE Node to Controller
The Alert On, Alert Off, Tamper, Keep Alive, On/Off/Toggle, Raw Fun messages are all items that
are sent over the link from the Node to the Controller. To send any of these messages you:
1) Select Message
2) Click Generate Button and note command generated
3) Press the Send button. This should generate an MCU < -- > CMND exchange in the VAR log
window and an incoming message in the Controller GUI log window
Alert On example is shown below:
1) The command generated by the VAR
2) The MCU < --- > CMND exchange on the Node Side. The CMND informs the MCU that it
received an ACK from the ULE Controller
3) The incoming message as seen on the graphical Log on the ULE Controller side:
4) The incoming message as seen parsed in the Log File on the ULE Controller side (This *.txt
file is located in the same directory as the DSPG Test Application.exe file):
28-05-2015 13:40:03:607 (1432809603607)
Target ---> Host: 29 00 00 00 16 30 21 00 00 30 17 00 01 00 00 00 00 02 00 00 00 03 01 00 00 01
01 06 00 02 04 00 00 00 01 00 0F 02 00 A5 FC
{CMBS_EV_DSR_HAN_MSG_RECV(12310)}
<CMBS_IE_HAN_MSG(12288)>:
Src: (type = 0, dev_id = 1, un_id = 0)
Dst: (type = 0, dev_id = 0, un_id = 2)
Transport : 0
Msg Sequence : 3, Message Type : 1
IF Type : 0, IF Id : 0x100, IF Member : 1
Data Len: 6
2
4
0
0
0
Alert Off, Tamper, Keep Alive, On/Off/Toggle work similarly to the example above.
Rev1.0
ULE Starter Kit User's Manual
1
June 2015
12