CONNECTING THE OUTPUT
The Single Station Remote Alarm activates a set of relay contacts in response to an alarm condition. This set
of relay contacts can be connected to any external device that is activated by the opening or closing of a switch.
Examples would be CONCOA's telephone dialer, a Warning Light, an external buzzer, or another monitoring
or alarm system. Whatever the connecting device, care must be taken not exceed the rating of the relay contacts
(Table 3). Refer to Table 4 for the pin assignments for the Output Connector.
Pin Number
Table 3
Relay Contact Rating
24 VDC
115 VAC
Cable Retainer Tabs
Cable Cover
Cable Retainer
Figure 7
Table 4
Function
1
2
Relay Output
3
4
Unused
notch
Figure 8
1 amp Resistive Load
0.5 amp Resistive Load
Locking Nut
Contact
Common (C)
Normally Closed (N.C.)
Normally Open (N.O.)